just DIY team, home

Furnace not heating? The two checks that pointed to our igniter

Blog

Our furnace stopped heating one November, right when it got cold. This is how we found the bad part. It is not a step-by-step repair guide: it is what we saw on ours, in the order we saw it.

Before anything else: a furnace has gas and 120 volt power. Shut off the power, and the gas if needed, before you replace parts. We are not HVAC professionals. When in doubt, call a licensed HVAC technician.

Check 1: watch what the furnace does when it starts

Ours started its cycle. The inducer motor ran. Then nothing: the hot surface igniter never glowed.

That narrowed it down. The furnace was trying to start, and it stopped at the igniter.

Check 2: is power reaching the igniter?

We checked with a meter: 120 volts was reaching the igniter.

So the power was fine. The furnace was sending the igniter what it needed, and the igniter was doing nothing with it. That made the igniter the bad part.

The new igniter

We replaced it, and checked the new one with the meter: about 77.9 ohms. The range we had read was normal is 40 to 200 ohms, so the new part was inside it.

What to take from this

  • If the inducer runs and the igniter never glows, the igniter is worth checking.
  • A meter answers the question in two readings: voltage reaching the igniter, and the resistance of the igniter itself.
  • If you are not comfortable working around gas and line voltage, this is a job for a licensed technician.