Furnace Not Heating? How I Diagnosed a Bad Hot Surface Igniter

FixHome Fixes & RepairsAug 25, 20252:51

Our furnace stopped heating one November, right when it got cold. The inducer motor ran, but the hot surface igniter never glowed. A meter showed 120 V reaching the igniter, so the power was fine and the igniter was bad. I replaced it and checked the new one: about 77.9 ohms, inside the 40 to 200 ohm range I'd read was normal. This isn't a step-by-step tutorial, just how I diagnosed mine.

Symptom
Inducer runs, igniter never glows
The test
120 V reaching the igniter
New igniter
About 77.9 ohms (40 to 200 is normal)

Round by round

  1. 0:00Intro and disclaimer
  2. 0:49What was wrong
  3. 1:11Inducer runs, igniter doesn't
  4. 1:23Checking for 120 V at the igniter
  5. 1:51Testing the new igniter (77.9 ohms)
  6. 2:28Ending

Safety first

A furnace has gas and 120 V power. Shut off the power (and the gas if needed) before you replace parts. I'm not an HVAC professional and this isn't a step-by-step tutorial: when in doubt, call a licensed HVAC technician.